Skip to content
Professional Sewer & Drain Services logo

Commercial and property managers

Grease Trap and Drain Maintenance for Restaurants

Published November 1, 2026. Updated November 1, 2026.

Stainless steel prep line and tiled floor in a small restaurant kitchen before service

Restaurant drain maintenance comes down to three habits: keep grease out of the drains, keep the grease interceptor serviced on a written schedule, and keep the lines below it clear. When a kitchen drain backs up, it is more than a plumbing problem. Food regulators treat sewage in a food area as a reason to stop serving.

What Does Illinois Require for Grease Interceptors?

Illinois sets the baseline in its Plumbing Code, 77 Ill. Adm. Code 890, administered by the Illinois Department of Public Health. Subpart E covers interceptors and separators, and section 890.510 is titled Grease Interceptor Requirements. The code defines a grease interceptor as a device that separates and retains grease, oils and other floating matter from sewage waste while the remaining flow goes on to the drain.

We are not quoting sizing here. The version we read is IDPH's 2019 rulemaking text, so confirm the adopted version, and let your plumber and the building department decide size at plan review.

A city can add its own rules on top. Ask the City of Washington's public works office three things: whether it has a grease ordinance, how often it requires the interceptor to be cleaned, and what records it expects. For the kitchen itself, IDPH says local food protection programs set standards and conduct inspections. In Tazewell County, that is the county health department in Tremont, listed at 309-925-5511. Confirm which office covers your address.

Kitchen drain backing up during service? Call (209) 563-1400

Open 7 days, 7:15 AM to 6:15 PM. Tell us what is happening and we will give you a clear, upfront quote.

What Should the Kitchen Do Every Shift?

The kitchen does most of the work, because grease that never enters the drain never has to be removed. These habits cost nothing:

  • Scrape plates dry into the trash before they reach the sink.
  • Seat a strainer in every sink and floor drain, and empty it each shift.
  • Catch used fryer oil in a lidded container for pickup. Never pour it down a drain.
  • Wipe pots and pans with a paper towel before washing.
  • Keep food waste out of the interceptor unless the design allows it.
  • Write it down. A one-page log of cleanings and ticket numbers is the first thing an inspector asks to see.
Removable basket strainer seated in a floor drain on a quarry tile kitchen floor
A basket strainer in a kitchen floor drain catches food scraps.

Which Jobs Fill an Interceptor Faster?

Some of the biggest loads come from cleaning, not cooking. Sioux City, Iowa's grease program warns that vent hood and exhaust cleaning, floor mats and heavily soiled utensils all fill the device faster, so plan the next clean-out around them. Its best-practice list adds three habits worth copying:

  • Keep wash water under 140°F, the limit that list sets.
  • Send mat and mop water through a utility sink connected to the interceptor.
  • Sweep floors before wash-down, so solids go in the trash.

Dairy counts too. Sioux City's sheet sets a 400 mg/L discharge limit for grease and oil, and lists whole milk at 37,000 mg/L and ranch dressing at 470,000. That limit is Sioux City's, not a local one, but the comparison shows why a bakery or coffee shop has a grease problem as well.

Trap or Interceptor: What Changes for Maintenance?

The device decides who cleans it and how it is sized. A trade article in PHCPPros describes gravity units as large central tanks and hydromechanical units as smaller, local ones.

Hydromechanical unitGravity interceptor
Typical locationRecessed in the floor, or on it for a single sinkBuried outside, or in a garage with truck access
Sized byWaste flow in gallons per minuteTank volume, by a method the code sets
Cleaned byStaff or a hauler, where local rules allow itA hauler with a vacuum truck
Sioux City's example ruleAt least weekly, or sooner at 25%Pumped when it reaches 25%

Those intervals are one Iowa city's ordinance, not a Washington rule. They are useful as a sense of scale.

How Often Should a Grease Interceptor Be Cleaned?

We did not find one number that applies to every kitchen, so we will not invent one. The right interval depends on the interceptor's size, how much grease the kitchen produces, and any rule the city sets. The practical method is to check the interceptor, note how fast it fills, and set the schedule from that.

The 25% Rule, With the Math

Many sewer authorities set a measure rather than a date, and the common one is 25%. Under Sioux City's version, floating grease plus settled solids cannot reach a quarter of the liquid depth. Its worked example has 0.5 feet of grease and 1 foot of solids in 4 feet of contents. That is 1.5 divided by 4, or 37.5%, so the kitchen fails and needs to pump more often.

We have not confirmed that Washington uses this measure, so ask public works. Even without a rule, it gives you a target. Have the hauler record both depths on the ticket for a few cycles, and you will see how fast your kitchen fills. Sioux City also says to witness each cleaning, which is the easiest way to know the job was finished.

Three different people handle three different jobs:

TaskWhoHow often
Scrape, strain, catch oilKitchen staffEvery shift
Pump out the interceptorA grease haulerSet by size, volume and local rules; keep each ticket
Clear and jet the linesA plumberBased on what a camera shows beyond the trap

Pumping is a separate trade from plumbing. What we do is commercial drain service: cutting and jetting the lines on either side of the interceptor. Hydro jetting scours grease from pipe walls where a cable only punches a hole through it. Our comparison of snaking and hydro jetting explains when each fits.

Open access lid of an in-floor grease interceptor showing a thick layer of grease
An interceptor opened for service shows how much grease it has caught.

What Do You Do When Sewage Backs Up Into the Kitchen?

Stop serving food from the affected area and call the health department. Illinois rules come from IDPH and your local health department, so we cite the model here, not a state rule. The FDA Food Code is the model regulators use to write their own rules. Wisconsin and Indiana guidance, both written from that model, say the same things:

  1. Close or stop operating if sewage keeps backing up from a floor drain, toilet, sink or other fixture. Wisconsin says to discontinue all operations in that case.
  2. Stop food preparation if no handwashing sink works and you cannot set up an alternative. Operation must also cease if employees have no working toilet.
  3. Report it. Indiana says an owner or operator must close and report to the regulatory authority for a single backup event.
  4. Discard contaminated food and take affected fixtures out of service.
  5. Clean spills with detergent, then a sanitizer.

Ask your health department what it requires before you reopen. Then call a plumber, and photograph the drain and the water before anything is cleaned up. Our post on plumbing emergencies for property managers covers building-level planning.

High-pressure jetting hose and nozzle being fed into a commercial floor drain
A jetting hose entering a commercial kitchen drain line.

What We Check on a Kitchen Line Before We Touch It

We begin with the symptoms. Is it one sink or every drain? Does the floor drain slow first, and does it gurgle when the dish machine empties? A pattern across fixtures puts the problem in the line they share, not in a single trap.

Then we look at the plumbing around the interceptor, the cleanouts we can reach, and what comes out on the cable or jetter. A camera pass beyond the interceptor shows whether grease has coated the pipe wall, and that tells you how soon the line will need attention again. Ask any plumber for the license number before work starts, since Illinois requires it in advertising. For a restaurant in Sunnyland, about four miles from our base, call first and we will tell you what we can do.

Lidded plastic container of used fryer oil beside a restaurant back door
Used fryer oil kept in a lidded container for pickup, not poured down a drain.

Scheduled Cleaning or Wait for the Clog?

  • Scheduled line cleaning costs money when nothing looks wrong, and you pick a slow morning for it. A kitchen with heavy fryer volume usually comes out ahead.
  • Waiting costs nothing until the backup lands during service. Then you pay for the line, the lost shift and any health department steps.
  • Too much jetting has a cost as well. Old pipe should be checked with a camera before it gets repeated pressure.

The honest answer depends on the first few cleanings. If little comes out, stretch the interval. If the same line is coated again in weeks, look harder at what goes down the drain.

Set the Schedule Before the Next Rush

Call (209) 563-1400 and tell us which drains slow first, when the interceptor was last pumped and when your kitchen is quiet. We will talk through a first cleaning and a camera pass, and you get a clear, upfront quote before work starts.

Sources

Written by the Professional Sewer & Drain Services team

A plumbing and sewer company based in Washington, IL. About us

Common Questions

Does my restaurant need a grease trap?
The Illinois Plumbing Code has a section titled Grease Interceptor Requirements, 77 Ill. Adm. Code 890.510, and commercial kitchens are what it is written for. Whether your kitchen needs one, and what size, is decided at plan review. Ask the City of Washington building department, and have your plumber confirm the design before the pipes are closed in.
Will hot water and soap push grease through the line?
It moves grease downstream, but it does not remove it. Hot water thins grease, and the grease cools and sets again once it travels further along the pipe. Scraping, straining and catching fryer oil in a container do far more than rinsing, which only moves the problem.
Who pumps out the grease interceptor?
A grease hauler, not a plumber. Pumping interceptors is a separate trade from plumbing. What a plumber does is clear and jet the lines on both sides of the interceptor and camera them. Ask your hauler for a service ticket each time, and keep the tickets with your cleaning log.
What are the early signs that a kitchen drain is about to clog?
Floor drains that slow down, gurgling at the dish pit when a sink drains nearby, a sour smell near the interceptor, and grease on the lid or the walls of the trap. Any of these is a call before service, not after. A camera pass shows how much grease coats the line beyond the trap.
Does a coffee shop or bakery need to think about grease?
Yes, because grease is not only fryer oil. Milk, cream, butter and icing all carry fat, and Sioux City, Iowa's grease sheet lists whole milk at 37,000 mg/L against a 400 mg/L discharge limit. A small kitchen sends less volume, but a slow floor drain at the steam pitcher sink is often the first warning. Ask public works what applies to your shop.

Plumbing problem right now? Call (209) 563-1400

Open 7 days, 7:15 AM to 6:15 PM. Tell us what is happening and we will give you a clear, upfront quote.

Call (209) 563-1400Quote